Milliplex Kit¿Í Luminex ½Ã½ºÅÛÀ» ÇÔ²² »ç¿ëÇÏ¿©, ÀûÀº ¾çÀÇ »ùÇ÷ΠÇѹø¿¡ ¿©·¯ BiomarkerµéÀ» µ¿½Ã¿¡ ºÐ¼®ÇÒ ¼ö ÀÖ½À´Ï´Ù. Cytokine/Chemokine, Cell Signaling, ImmunoglobulinÀ» ¼Õ½±°Ô Á¤·®Çϼ¼¿ä. |
|
||
| Merck Millipore | |||
| 10 different proteins in 80 test samples ºÐ¼® ½Ã |
Milliplex Kit | ELISA |
|---|---|---|
| Number of plates required | ![]() |
![]() |
| 1 | 10 | |
| Total time to result | 3 hours | 10 hours |
| Results per plate | 800 | 80 |
| Total sample used per panel | 50 ul | 4 ml |
| Internal controls possible? | Yes | No |
| Dynamic Range | 1-10,000 pg/ml | 10-2,500 pg/ml |
| Lower limit of detect | ~ 1 pg/ml | ~ 1 pg/ml |
| Assay | Mesures Secreted protein Levels |
Ease of Assay | High Sensitivity | Quick Results | Low Cost | Multiplex Capability |
|---|---|---|---|---|---|---|
| ELISA | ¡Û | ¡Û | ¡Û | |||
| Enzyme-linked Immunospot | ¡Û | ¡Û | ||||
| BioAssays | ¡Û | ¡Û | ¡Û | |||
| Ribonuclease Protection Assay |
¡Û | ¡Û | ||||
| Reverse Transcrptase Polymerase Chain Reaction |
¡Û | ¡Û | ¡Û | |||
| Milliplex¢â Multiplex Assay | ¡Û | ¡Û | ¡Û | ¡Û | ¡Û | ¡Û |
Milliplex-Luminex ½Ã½ºÅÛÀº Suspension Array Technology(SAT)¸¦ ½ÇÇöÇÑ »õ·Î¿î array systemÀÔ´Ï´Ù. ±âÁ¸ÀÇ Æ¯Á¤Àå¼Ò¿¡ probe°¡ °íÁ¤µÈ ÆòÆÇ ŸÀÔÀÇ ½Ã½ºÅÛµéÀº °¢ Àå¼Ò¿¡ °íÁ¤µÇ¾î ÀÖ´Â probe°¡ ¹«¾ùÀÎÁö Ç¥ÁöÇϱâ À§Çؼ Àå¼Ò¸¦ ÁöÁ¤ÇÏ´Â À§Ä¡ Á¤º¸°¡ »ç¿ëµÇÁö¸¸, SAT¿¡¼´Â ½Äº° Äڵ带 ºÎ¿©ÇÑ bead Ç¥¸é¿¡ probe¸¦ °íÁ¤ÇØ, ÀÌ beadÀÇ ½Äº° Äڵ带 Àо´Â °ÍÀ¸·Î Ç¥¸é¿¡ °íÁ¤µÇ¾î ÀÖ´Â probe¸¦ ¾Ë ¼ö ÀÖ½À´Ï´Ù.
|
Luminex ½Ã½ºÅÛ¿¡¼´Â, ´ãü·Î¼ Á÷°æ 5. 6¥ìmÀÇ polystyreneÁ¦ Microbeads »ç¿ëÇØ, ÀÌ Microbeads¸¦ ¿©·¯°¡Áö ³óµµ¿¡ Æí¼ºÇÑ 2»öÀÇ Çü±¤ »ö¼Ò·Î ¿°»öÇØ, °¢ Çü±¤ »ö¼ÒÀÇ ÇÔÀ¯·®À» ½Äº° ÄÚµå·Î¼ ÀÌ¿ëÇϰí ÀÖ½À´Ï´Ù. ±¸Ã¼ÀûÀ¸·Î´Â, °¢ Çü±¤ »ö¼Ò¿¡ ºÙ¾î, detection sensor·Î È®½ÇÈ÷ ±¸º° °¡´ÉÇÑ 10 ´Ü°èÀÇ ³óµµ¸¦ ¼±Á¤ÇÕ´Ï´Ù. ±×°ÍÀ» 100¹è ÇÏ¿© 100 Á¾·ùÀÇ Microbeads¸¦ ÀÛ¼ºÇÕ´Ï´Ù. »ö ¸¶´Ù ´Ù¸¥ ¹°ÁúÀ» °íÁ¤ÇÑ Luminex beads ¼¼Æ®¸¦ ÁغñÇØ, ÀÌ beads ¼¼Æ®¿Í reporter Çü±¤ ¹°Áú·Î Ç¥Áö ÇÑ »ùÇÃÀ» Æ©ºê Áß(¾È)¿¡¼ ¹ÝÀÀ ½Ãŵ´Ï´Ù. ¡é
»ùÇà °áÇÕ ÈÄ, fluorometry ¿¡ ÀÇÇØ Luminex beads¸¦ Çϳª¾¿ È긮¸é¼, Àû»ö ·¹ÀÌÀú¿Í APD ¼¾¼·Î beadsÀÇ Á÷°æ°ú »öÀ» ÃøÁ¤ÇØ, ³ì»ö ·¹ÀÌÀú¿Í ±¤ÀüÀÚÁõ¹è°ü¿¡¼ »ùÇÃÀÇ °áÇÕ¾çÀ» ÃøÁ¤ÇÕ´Ï´Ù |
|
Milliplex cytokine detection systems are sandwich immunoassays performed on unique fluorescent beads, which contain a precise distribution of two fluorescent dyes, and a specific cytokine capture antibody linked to its surface. The fluorescent bead sets are incubated with a biological sample. A biotinylated cytokine reporter antibody is then used to identify the captured cytokine bound to the specific fluorescent bead. The reaction is detected by adding a streptavidin-phycoerythrin conjugate to the reaction mixture and read in a Luminex 100 instrument.